1000-1017 |
Wrong lamp/ no communication with lamp |
|
Check lamp type Check lamp type Call a qualified service engineer |
1697 |
no communication with formatter ctrl |
|
|
Call a qualified service engineer |
|
|
|
1696 |
no communication with formatter |
|
|
Call a qualified service engineer |
|
|
|
1695 |
no communication with red formatter |
|
|
Call a qualified service engineer |
|
|
|
1694 |
no communication with green formatter |
|
|
Call a qualified service engineer |
|
|
|
1693 |
no communication with blue formatter |
|
|
Call a qualified service engineer |
|
|
|
1692 |
formatter ‘Power Good’ signal not OK |
|
|
Call a qualified service engineer |
|
|
|
2000 |
no communication with lamp powersupply |
|
Call a qualified service engineer |
|
|
|
2001 |
mains voltage too low |
|
|
|
Call a qualified service engineer |
|
|
|
2002 |
Hot restrike Lamp with many strikes maximum run time exceeded Lamp or LPS or SPG failed |
Let cool down the lamp for at least 5 minutes Retry a few times Replace the lampwith a new one Replace LPS or SPG or cabling |
2003 |
mains voltage too high |
|
|
|
Call a qualified service engineer |
|
|
|
2004 |
Lamp goes out |
|
|
|
Call a qualified service engineer |
|
|
|
2005 |
Lamp stop failed |
|
|
|
Call a qualified service engineer |
|
|
|
2201 |
PFC start failed |
|
|
|
Replace LPS |
|
|
|
2501 |
PFC start failed |
|
|
|
Replace LPS |
|
|
|
2801 |
PFC start failed |
|
|
|
Replace LPS |
|
|
|
2202 |
LFC start failed |
|
|
|
Replace LPS |
|
|
|
2502 |
LFC start failed |
|
|
|
Replace LPS |
|
|
|
2802 |
LPS (address 0x28) |
|
|
|
Replace LPS |
|
|
|
2203 |
LPS (address 0x20) |
|
|
|
Replace LPS |
|
|
|
2503 |
LPS (address 0x22) |
|
|
|
Replace LPS |
|
|
|
2803 |
LPS (address 0x28) |
|
|
|
Replace LPS |
|
|
|
2206 |
hot restrike,lamp with many strikes, maximum run time exceeded |
Let cool down the lamp for at least 3 minutes. Replace the lamp or SPG with a new one If problem persists, call a qualified service engineer |
2506 |
hot restrike,lamp with many strikes, maximum run time exceeded |
Let cool down the lamp for at least 3 minutes. Replace the lamp or SPG with a new one If problem persists, call a qualified service engineer |
2806 |
hot restrike,lamp with many strikes, maximum run time exceeded |
Let cool down the lamp for at least 3 minutes. Replace the lamp or SPG with a new one If problem persists, call a qualified service engineer |
2207 |
lamp voltage too high or too low |
|
|
Replace lamp |
|
|
|
2507 |
lamp voltage too high or too low |
|
|
Replace lamp |
|
|
|
2807 |
lamp voltage too high or too low |
|
|
Replace lamp |
|
|
|
2208 |
lamp voltage too high or too low |
|
|
Replace lamp |
|
|
|
2508 |
lamp voltage too high or too low |
|
|
Replace lamp |
|
|
|
2808 |
lamp voltage too high or too low |
|
|
Replace lamp |
|
|
|
4000 |
Incompatible hardware used |
|
|
|
Change to correct hardware |
|
|
|
4199 |
no communication with FIB |
|
|
|
Call a qualified service engineer |
|
|
|
5098 |
Internal Backup device has reached its maximum capacity |
Call a qualified service engineer |
|
|
|
5097 |
Internal Backup device has reached its maximum capacity |
Call a qualified service engineer |
|
|
|
5096 |
Storing the custom settings into internal backup device has failed |
If problem persists, call a qualified service engineer |
|
|
5095 |
Restoring the custom settings from internal backup device has failed |
If problem persists, call a qualified service engineer |
|
|
7698 |
High temperature on light pipe entry |
|
|
If problem persists, call a qualified service engineer |
|
|
7697 |
Temperature sensor on light pipe not connected |
|
Call a qualified service engineer |
|
|
|
7696 |
Temperature sensor on light pipe shorted |
|
Call a qualified service engineer |
|
|
|
7695 |
Low temperature on red DMD |
|
|
|
Switching on the lamp will heat up the DMD |
|
|
7694 |
High temperature on red DMD |
|
|
Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer |
7693 |
Temperature sensor on Red DMD not connected |
|
Call a qualified service engineer |
|
|
|
7692 |
Temperature sensor on Red DMD shorted |
|
Call a qualified service engineer |
|
|
|
7691 |
Low temperature on green DMD |
|
|
Switching on the lamp will heat upthe DMD |
|
|
7690 |
High temperature on green DMD not connected |
|
Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer |
7689 |
Temperature sensor on green DMD |
|
|
Call a qualified service engineer |
|
|
|
7688 |
Temperature sensor on green DMD shorted |
|
Call a qualified service engineer |
|
|
|
7687 |
Low temperature on blue DMD |
|
|
Switching on the lamp will heat upthe DMD |
|
|
7686 |
High temperature on blue DMD |
|
|
Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer |
7685 |
Temperature sensor on blue DMD not connected |
|
Call a qualified service engineer |
|
|
|
7684 |
Temperature sensor on blue DMD shorted |
|
Call a qualified service engineer |
|
|
|
7676 |
High temperature on front DMD cooling block |
|
Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer |
7675 |
Temperature sensor on front cooling block not connected |
Call a qualified service engineer |
|
|
|
7674 |
Temperature sensor on front cooling block shorted |
Call a qualified service engineer |
|
|
|
7672 |
High temperature on red DMD cooling block |
|
Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer |
7671 |
Temperature sensor on red DMD cooling block not connected |
Call a qualified service engineer |
|
|
|
7670 |
Temperature sensor on red DMD cooling block shorted |
Call a qualified service engineer |
|
|
|
7668 |
High temperature on green DMD cooling block |
|
Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer |
7667 |
Temperature sensor on green DMD cooling block not connected |
Call a qualified service engineer |
|
|
|
7666 |
Temperature sensor on green DMD cooling block shorted |
Call a qualified service engineer |
|
|
|
7664 |
High temperature on blue DMD cooling block |
|
Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer |
7663 |
Temperature sensor on blue DMD cooling block not connected |
Call a qualified service engineer |
|
|
|
7662 |
Temperature sensor on blue DMD cooling block shorted |
Call a qualified service engineer |
|
|
|
7660 |
High temperature on engine |
|
|
|
Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer |
7659 |
Temperature sensor on engine notconnected |
|
Call a qualified service engineer |
|
|
|
7658 |
Temperature sensor on engineshorted |
|
|
Call a qualified service engineer |
|
|
|
7999 |
fan is running too slow or not at all |
|
|
If problem persists, call a qualified service engineer |
|
|
7997 |
fan is running too slow or not at all |
|
|
If problem persists, call a qualified service engineer |
|
|
7995 |
fan is running too slow or not at all |
|
|
If problem persists, call a qualified service engineer |
|
|
7993 |
fan is running too slow or not at all |
|
|
If problem persists, call a qualified service engineer |
|
|
7991 |
fan is running too slow or not at all |
|
|
If problem persists, call a qualified service engineer |
|
|
7989 |
fan is running too slow or not at all |
|
|
If problem persists, call a qualified service engineer |
|
|
7987 |
fan is running too slow or not at all |
|
|
If problem persists, call a qualified service engineer |
|
|
7985 |
low temperature on dmd |
|
|
|
turning on the lamp will heat up the dmd |
|
|
|
7984 |
high temperature on dmd |
|
|
|
check if air slot are free; clean airfilters If problem persists, call a qualified service engineer |
7983 |
low temperature on dmd |
|
|
|
turning on the lamp will heat up the dmd |
|
|
|
7982 |
high temperature on dmd |
|
|
|
check if air slot are free; clean airfilters If problem persists, call a qualified service engineer |
7981 |
low temperature on dmd |
|
|
|
turning on the lamp will heat up thedmd |
|
|
|
7980 |
high temperature on dmd |
|
|
|
check if air slot are free; clean airfiltersIf problem persists, call a qualified service engineer |
7978 |
high temperature lamp |
|
|
|
check if air slot are free; clean airfilters If problem persists, call a qualified service engineer |
7976 |
high temperature on smps |
|
|
|
check if air slot are free; clean airfilters If problem persists, call a qualified service engineer |
7974 |
ambient temperature abovespecification |
|
check ambient conditionscheck if air slot are free; clean airfilters |
7973 |
ambient temperature abovespecification |
|
Hardware problem in Fan controlboard, call a qualified serviceengineer |
7972 |
voltage on fan group 1 too high |
|
|
Hardware problem in Fan controlboard, call a qualified serviceengineer |
7971 |
voltage on fan group 2 too low (=anode fan) |
|
Hardware problem in Fan controlboard, call a qualified serviceengineer |
7970 |
voltage on fan group 2 too high |
|
|
Hardware problem in Fan controlboard, call a qualified serviceengineer |
7969 |
voltage on fan group 3 too low (=engine fan) |
|
Hardware problem in Fan controlboard, call a qualified serviceengineer |
7968 |
voltage on fan group 3 too high |
|
|
Hardware problem in Fan controlboard, call a qualified serviceengineer |
7967 |
voltage on fan group 4 too low (=cold mirror + head ex. fan) |
Hardware problem in Fan controlboard, call a qualified serviceengineer |
7966 |
voltage on fan group 4 too high (=cold mirror + head ex. fan) |
Hardware problem in Fan controlboard, call a qualified serviceengineer |
7965 |
voltage on fan group 5 too low (=mains input fan) |
|
Hardware problem in Fan controlboard, call a qualified serviceengineer |
7964 |
voltage on fan group 5 too highmains input fan) |
|
Hardware problem in Fan controlboard, call a qualified serviceengineer |
7963 |
voltage on fan group 6 too low (=smps fan) |
|
Hardware problem in Fan controlboard, call a qualified serviceengineer |
7962 |
voltage on fan group 6 too low (=smps fan) |
|
Hardware problem in Fan controlboard, call a qualified serviceengineer |
7959 |
voltage on pump too low |
|
|
|
If problem persists, call a qualified service engineer |
|
|
7958 |
voltage on pump too high |
|
|
|
If problem persists, call a qualified service engineer |
|
|
7957 |
supply voltage for fans too low |
|
|
If problem persists, call a qualified service engineer |
|
|
7956 |
supply voltage for fans too high |
|
|
If problem persists, call a qualified service engineer |
|
|
7955 |
supply voltage for DMD cooling toolow |
|
|
If problem persists, call a qualified service engineer |
|
|
7954 |
supply voltage for DMD cooling toohigh |
|
|
If problem persists, call a qualifiedservice engineer |
|
|
7953 |
supply voltage for motors too low |
|
|
If problem persists, call a qualifiedservice engineer |
|
|
7952 |
supply voltage for motors too high |
|
|
If problem persists, call a qualifiedservice engineer |
|
|
7945 |
supply voltage for electronics toolow |
|
|
If problem persists, call a qualifiedservice engineer |
|
|
7944 |
supply voltage for electronics toohigh |
|
|
If problem persists, call a qualifiedservice engineer |
|
|
7943 |
supply voltage for engineelectronics too low |
|
If problem persists, call a qualifiedservice engineer |
|
|
7942 |
supply voltage for engineelectronics too high |
|
If problem persists, call a qualifiedservice engineer |
|
|
7941 |
supply voltage for drawerelectronics too low |
|
If problem persists, call a qualifiedservice engineer |
|
|
7940 |
supply voltage for drawerelectronics too high |
|
If problem persists, call a qualifiedservice engineer |
|
|
7939 |
projection lens to close to prism |
|
|
move lens away from prism (upand/or right) |
|
|
7938 |
lamp module not correctly inserted |
|
|
reinsert lamp module and screw firmly |
|
|
|
7937 |
bad or no water flow in cooling circuit |
|
|
If problem persists, call a qualified service engineer |
|
|
7936 |
tilt angle is out of specifications |
|
|
Correct projection installation.Change the tilting so that thetilt angle becomes within thespecifications |
7935 |
engine is not correctly inserted |
|
|
If problem persists, call a qualifie dservice engineer |
|
|
7934 |
formatter interface board is not correctly inserted |
|
If problem persists, call a qualified service engineer |
|
|
7931 |
high temperature on smps |
|
|
|
check if air slot are free; clean airfilters If problem persists, call aqualified service engineer |
7929 |
high temperature on smps |
|
|
|
check if air slot are free; clean airfilters If problem persists, call aqualified service engineer |
7928 |
extreme overheating of dmd’s or lamp |
|
|
If problem persists, call a qualified service engineer |
|
|
7927 |
fan is not running or is running tooslow |
|
|
If problem persists, call a qualified service engineer |
|
|
8000 |
|
|
|
|
If problem persists, call a qualified service engineer |
|
|
8001 |
|
|
|
|
If problem persists, call a qualified service engineer |
|
|
8002 |
|
|
|
|
If problem persists, call a qualified service engineer |
|
|
9000 |
Initialization of the scaler failed |
|
|
If problem persists, call a qualified service engineer |
|
|
9198 |
BW or refresh rate of input sourcetoo high |
|
If problem persists, call a qualified service engineer |
|
|
9398 |
Reaching the maximum allowednumber of files |
|
Delete some unnecessary files |
|
|
|
10498 |
Module with obsolete firmware |
|
|
Call a qualified service engineer |
|
|
|